Taiwan Mosi Corporation


Taiwan Mosi Corporation
The wastewater discharged from semiconductor factories contains many strong acids, especially HF and H₂SO₄. The concrete surface of the wastewater treatment tank and the surface of the iron sedimentation tank must be protected with FRP lining.
Concrete primer resin SWANCOR CP95, iron trough primer resin SWANCOR 984-M, corrosion-resistant resin SWANCOR 901
After applying the primer resin, the structural part is impregnated with SWANCOR 901 layer of chopped strand mat, and the part in contact with wastewater is covered with polyester organic surface mat, forming a corrosion-resistant layer rich in resin.